| The LinTronic
TableTop is capable of monitoring and controlling ICPDAS 7000-series which is a low-cost
range of professional modules offering a mixture of digital inputs and outputs. Find
international ICPDAS dealer at www.icpdas.com
7000 series overview - click ... 7000 series
manual - click

Note: TableTop must be
jumpered to work on RS485 as the ICPDAS modules work on the DCON protocol on a 2-wire
industrial RS485 bus.
Use the DCON Utility tool to set the baudrate
to the same baudrate as the Tabletop (default 19.200 bps) and enable Checksum.


ICPDAS triggers |
|
| The TableTop may
scan the On/Off status of the first 1 to 8 inputs on the first 1 to 16 ICP addresses. We support input scanning of the following modules:
7041, 7044, 7050, 7052, 7053, 7058, 7060, 7063, 7065.
Scanning up to 128 inputs by RS485 - click
Scanning ICPDAS modules inputs require that the
"ICPDAS input scanning" feature to be enabled as the input scanning requires a
lot of micro-processor resources.
See Features - click
If you have the need for reading/scanning inputs of ICPDAS
modules, then please contact LinTronic.
Note: Scanning of the inputs will start 30
seconds after TableTop is powered up, unless ther TableTop is accessed by the SETUP
program within these 30 seconds. This will allow you to change configuration of the Input
scanning in for example the TT455-RT-238 Memory Map. When the scanning starts up it is not
possible to contact the TableTop due to the heavy resources and the fast scanning on the
RS485 bus. |

|
7050 wired for input scanning

7065 wired for input scanning
 |
|
ICPDAS actions |
|
| The TableTop may
control the first 1 to 8 outputs of all 255 adresses of the ICPDAS 7000-series modules. We support the following ICPDAS 7000-series modules: 7042, 7043, 7044, 7050, 7060, 7063, 7065, 7066, 7067.
As it is somewhat time-consuming to upload all of the
commands to the internet database, we have only uploaded the commands for the first 16
addresses:
Commands: HOMEAUTOMATION, ICPDAS, ADR {1-16}
If you have the need for controlling more than these 128
outputs, then please contact LinTronic.
Controlling up to 2.040 ICPDAS outputs/relays by RS485 - click |

|

|
|