Settings, Inputs
Use the Get button to collect current
settings. Use the Set button to change current settings.
TableTop hardware version 5: 2 digital inputs
TableTop hardware version 4: 1 digital input
| Digital
Inputs |
| Off |
Turns the input off.
Command 908 may still request current
InputStatus. |
| Standard |
Reports the input
On/Off status changes to the computer and upon request by Command 908. |
| Telephone Automutic |
Instructs the input
to monitor the attached TelephoneRelay AutoMutic.
Command 910 sends the
TelephonLine conditions to the computer.
The TelephoneLine status can be used as Trigger. |
| PIR |
Instructs the input
to monitor the attached motion detector.
Command 911 sends the PIR conditions to
the computer.
The PIR status can be used as Trigger. |
|
| IR
Reception |
| Off |
Turns IR reception
off. Can be usefull if you only want to control the box from the 2-wire RS485 network or
from the computer. |
| 455 & 38 |
Commands the device
to receive signals depending on connected IR receiver (internal or external)
(Hardware 4 only) |
| Int455 |
Commands the device
to receive 455 KHz signals (Bang&Olufsen) from the internal receiver. |
| Ext455 |
Commands the device
to receive 455 KHz signals (Bang&Olufsen) from an external receiver. |
| Int38 |
Commands the device
to receive 38 KHz signals from the internal receiver. |
| External |
Commands the device
to receive 16 - 80 KHz from an external receiver. |
|
Settings, Outputs
TableTop hardware version 5: 2 digital outputs
TableTop hardware version 4: 1 digital output
Use the Get button to collect current
settings. Use the Set button to change current settings.
| Digital
Outputs |
| Off |
Turns the Output
off. Command 909 may still request
current OutputStatus. |
| Standard |
Computer can turn
the Output On, Off, Pulse. |
| Remote Detection |
The Output will
produce a short pulse when a remote control code is received or transmitted. |
| IR edges |
The Output follows
the edges of the selected InfraRed receiver. |
| Conson |
Digital Output 1
controls a Conson Light System. See Conson below. |
| BeoSystem |
Digital Output 2
controls a BeoSystem. See ApplicationNote - click |
|
| LED
- Built-in TableTop LED is Red |
| Off |
Turns the LED off. Command 909 may still request current
OutputStatus. |
| Remote Detection |
The LED will produce
a short blink when a remote control code is received or transmitted. |
| IR edges |
The LED follows the
edges of the selected InfraRed receiver(s). Can be used to detect for infrared noise in
the actual environment. Can also be used to detect whether a remote control is
transmitting at the selected frequency range. Depending on the timelength of the pulses in
the actual code set, the LED blinking might hard to see. |
| Input x |
The LED follows the
On/Off status of Input x. If Input x is activated (grounded) the LED is On. You can use
this setting to monitor open/closed status of garagedoor, window, door, etc. |
| Output x |
The LED follows the
On/Off status of Output x. If Output x is On the LED is On. You can use this setting to
monitor On/Off status of an output controlling relays for Power, Light, etc. |
Status, Inputs/Outputs - On/Off
TableTop hardware version 5: 2 digital outputs
TableTop hardware version 4: 1 digital output
Use the Get button to collect current
settings. Use the SetOn/SetOff buttons to change current settings.
| Input x |
On means that the
Input is grounded. |
| Output x |
On means that the
Output is active. To control the Output select reuqired On/Off and click the related SetOn
or SetOff.
NOTE:
When you click SetOn only the Outputs marked as On will set to On. The Outputs marked as
Off will not be effected.
When you click SetOff only the Outputs marked as Off will set to Off. The Outputs marked
as On will not be effected. |
| 38 KHz |
This status is a momentary reading.
If you constantly read it as On, it means the receiver is On all the time.
Under normal conditions this should read Off most of the time. |
| 455 KHz |
This status is
a momentary reading. If you constantly read it as
On, it means the receiver is On all the time. This might
occur if you have an external receiver connected as their Automatic Gain Control (AGC) pick up a lot of background noise.
Under normal conditions this should read Off most of the time. |
| Flash |
Can be used to
create a programmable seriesof pulses on the LED or Output x.
The Green LED's in the TableTop cannot be controlled by users.
On - A value between 0 and 65000 (each unit is 4 ms)
Off - A value between 0 and 65000 (each unit is 4 ms)
Repeat - On - A value between 0 and 65000
Note: If you set Repeat to 65000, the 1 sec pulse ½ sec pause will run for ever.Example 1:
You want to produce a series of flashes on the red LED in the TableTop. The LED should be
on for 1 second, then off for ½ second, and you want this to run for 1 minute.
On = 250 ( 250 * 4 ms = 1 second )
Off = 125 ( 125 * 4
ms =
½ second )
Repeat = 40 ( 4x * 1½
second = 1 minute)
Example 2:
You want to produce a one second pulse on output 1 in order to control an electrical lock.
On = 250
Off = 0
Repeat = 1 (if you set Repeat to 0, it will never turn off) |
Passiv Infrared detector, PIR
TableTop hardware version 5: Enabled in
default software
TableTop hardware version 4: Not enabled in default software
Use the Get button to collect current
settings.
Command
911 sends the PIR conditions Idle or Active to the computer.
If you have a PIR motion detector connected to
Input x, you will see the PIR status change in the Status field when motion is detected
and when no motion is detected for a specific time.
If Active, the "Sec" and "Min" show the time since the PIR was last
activated.
If Idle, the "Sec" and "Min" show the time the PIR detector has been
idle.
You can use the PIR signals to Trigger Actions.
TelephoneRelay Status
TableTop hardware version 5: Enabled in
default software
TableTop hardware version 4: Not enabled in default software
Use the Get button to collect current
settings.
Command 910 sends the
TelephoneLine status to the computer.
If you have a TelephoneRelay AutoMutic connected to Input x, you
will see the line status change in the Status field if the phone rings, if you answer the
phone, if you make an outgoing call or the ringing stops.
You can use the Telephone signals to Trigger Actions.
|