Protocol command reference list |
ControlAction
Command: 039[ActionID][Par1][Par2][Par3][Par4][Par5][Par6][Repeat]
|
ActionID
761 = Digital output signals
Par1 = Brand (3-digit)
Par2 = Device (3-digit)
Par3 = Output (3-digit)
Par4 = Command (3-digit)
Par5 = Delay between (repetitions) (3-digit)
Par6 = Spare (3-digit)
| Par1 |
Par2 |
Par3 |
Par4 |
Par5 |
Par6 |
| 000 = LINTRONIC |
NA. |
NA. |
NA. |
NA. |
NA. |
| Brand |
TypeNumber |
ModuleNumber |
InputNumber |
On/Off |
NA. |
| 001 = CONSON |
001 = CP20
004 = CP70 |
001 - 004 |
001 - 008 |
000=Off
001=On |
000 |
| Example:
761001004002004001000001 = Conson, CP70, no. 2, Input 4, On |
| Brand |
Device |
Command |
Output |
NA |
NA. |
| 002 = PIONEER BUS |
161 = TAPE
162 = CD PLAYER
164 = TUNER
165 = AMPLIFIER
168 = LASER_DISC
171 = VCR
|
023 = PLAY
024 = PAUSE
022 = STOP
016 = FORWARD
017 = BACKWARD
028 = POWER |
001 = OUTPUT 1
002 = OUTPUT 2
|
000 |
000 |
| Example:
761002165028001000000001 = Pionner Bus, Amplifier, Power, TT455-RT-238's Output 1 |
Repeat ( 001 - 255 )
|
|
|