ControlAction
Command: 039[ActionID][Par1][Par2][Par3][Par4][Par5][Par6][Repeat]


ActionID

732 = RS485/RS232 text strings.

The text strings must be embedded in flash and are send when triggered by a 732-code.

In order to avoid communication or protocol problems, it is recommended that the TT455-RT-238 is programmed NOT to send any other commands onto the RS485/RS232 commport, than absolutely needed.
This means, turn off SendTriggerCommandsToBus.

Par1, Par 2 = Brand Par3, Par4 = Device Par5, Par6 = Command
000,000 = LG
Baudrate: Same as Lintronic.
Suggested: 9600 bps
000,000 = plasma screen, RS232 commands, 1-digit Commands can downloaded
from LinTronic database
000,001 = plasma screen, RS232 commands, 2-digit Commands can downloaded
from LinTronic database
000,001 = LUXOM LIGHT
Baudrate: Same as Lintronic.
Suggested: 9600 bps
000,000 = CLEAR, SYSTEM 0 000,000 = Group, Address
Group = 000 - 015
Address = 000 - 255
001,000 = SET, SYSTEM 0 000,000 = Group, Address
Group = 000 - 015
Address = 000 - 255
002,000 = TOGGLE, SYSTEM 0 000,000 = Group, Address
Group = 000 - 015
Address = 000 - 255
000,002 = VELLEMAN
Data send at fixed baudrate,
regardless of LinTronic
products: 2400 bps
DataProtocol: N,8,1
000,000 = Product, Number
000 = K8056/VM129, Number = 001 - 255
Commands can downloaded
from LinTronic database
000,003 = TOSHIBA
Baudrate: Same as Lintronic.
Suggested: 9600 bps
DataProtocol: N,8,1
000,000 = PROJECTOR (GENERIC) Commands can downloaded
from LinTronic database
000,004 = PIONEER
Baudrate: Same as Lintronic.
Suggested: 9600 bps
DataProtocol: N,8,1
000,000 = TV (GENERIC) Commands can downloaded
from LinTronic database
000,005 = PANASONIC
Baudrate: Same as Lintronic.
Suggested: 9600 bps
DataProtocol: N,8,1
000,000 = TV (GENERIC) Commands can downloaded
from LinTronic database
000,006 = NEC
Baudrate: Same as Lintronic.
Suggested: 9600 bps
DataProtocol: O,8,1
000,000 = TV Commands can downloaded
from LinTronic database
000,006 = NEC
Data send at fixed baudrate:
19200 bps
DataProtocol: N,8,1
000,001 = PROJECTOR Commands can downloaded
from LinTronic database
000,007 = SONY
Data send at fixed baudrate:
38400 bps
DataProtocol: E,8,1
000,000 = PROJECTOR (GENERIC) Commands can downloaded
from LinTronic database
000,008 = AMX
Data send at fixed baudrate:
38400 bps
DataProtocol: N,8,1
000,000 = NI-SERIES (RS232) Commands can downloaded
from LinTronic database
000,008 = AMX
Data send at fixed baudrate:
38400 bps
DataProtocol: N,8,1
000,001 = NI-SERIES (PROGRAM PORT) Commands can downloaded
from LinTronic database
000,009 = EPSON
Data send at fixed baudrate:
9600 bps
DataProtocol: N,8,1
000,000 = PROJECTOR, ESC/VP21 protocol Commands can downloaded
from LinTronic database
000,010 = GEHA 237
Data send at fixed baudrate:
9600 bps
DataProtocol: N,8,1
000,000 = PROJECTOR Commands can downloaded
from LinTronic database
000,011 = EXTRON AV SWITCH
Data send at fixed baudrate:
9600 bps
DataProtocol: N,8,1
000,000 = MAX44_88 series Commands can downloaded
from LinTronic database
000,012 = BOSE LIFESTYLE
Data send at fixed baudrate:
19200 bps
DataProtocol: N,8,1
000,000 = 18, 28, 38, 48 Commands can downloaded
from LinTronic database
000,012 = BOSE LIFESTYLE
Data send at fixed baudrate:
4800 bps
DataProtocol: N,8,1
000,001 = 50 Commands can downloaded
from LinTronic database
000,013 = CLIPSAL LIGHT
Data send at fixed baudrate:
9600 bps
DataProtocol: N,8,1
732000013GGGFFFTTTLLL001
732000013 = CLIPSAL LIGHT RS232
GGG = Group: 000 - 254
FFF = Function: 000 = Off, 001 = On, 002 = Ramp
TTT = Ramp Time: 0 sec to 17 minutes
LLL = Ramp level: 000 - 255
Commands can downloaded from LinTronic database or created by our SETUP configuration program
000,014 = MITSUBISHI
Data send at fixed baudrate:
9600 bps
DataProtocol: N,8,1
000,000 = 2000, 4000 SERIES PROJECTORS Commands can downloaded
from LinTronic database
000,015 = BARCO
Data send at fixed baudrate:
9600 bps
DataProtocol: N,8,1
000,000 = PROJECTOR Commands can downloaded
from LinTronic database
000,016 = HITACHI
Data send at fixed baudrate:
19200 bps
DataProtocol: N,8,1
000,000 = PROJECTOR Commands can downloaded
from LinTronic database
000,017 = CANON
Data send at fixed baudrate:
19200 bps
DataProtocol: N,8,2
000,000 = PROJECTOR Commands can downloaded
from LinTronic database
000,018 = IMERGE
Data send at fixed baudrate:
19200 bps
DataProtocol: N,8,2
000,000 = SOUNDSERVER Commands can downloaded
from LinTronic database
000,019 = INTELLIBUS
Data send at fixed baudrate:
19200 bps
DataProtocol: N,8,2
732000019000000ADRCOM001
732000019 = INTELLIBUS RS232
000000 = VERSION 1
ADR = Address - Intellibus pdf
COM = Command
Commands can downloaded from LinTronic database or created by our SETUP configuration program
000,020 = JVC
Data send at fixed baudrate:
19200 bps
DataProtocol: N,8,1
000,000 = PROJECTOR Commands can downloaded
from LinTronic database

Repeat ( 001 - 255 )