This command instructs the products output to
send a Conson databus command in order to control a www.conson.dk
Light System.
To see electrical interface - click
The command can be executed by any TableTop
product offering B&O reception and digital Output 1.
Output 1 must be set to ConsonOutput by command 36.
Module ( 1 digit )
1 = CP20 (input module, supported 64 commands)
2 = CP70A (not supported)
3 = CP70B (not supported)
4 = CP70C (RF module, supported 64 commands)
5 = CP70D (not supported)
Number ( 1 digit )
1 to 4 = Module 1 to 4
Input ( 1 digit )
1 to 8 = Input 1 to 8
OnOff ( 1 digit )
0 = Off, 1 = On
Syntax example
<32000151231034> |
< = Start
of package
32 = TO address ( device )
00 = FROM address ( computer )
015 = ConsonCommand
1 = Module ID
2 = Module Number
3 = Input Number
1 = Input On
034 = Checksum
> = End of package |
Respond
<00320151140> |
< = Start
of package
00 = TO address ( computer )
32 = FROM address ( device )
015 = ConsonCommand
1 = Output set to Conson, 0 = Output not set to Conson
140 = Checksum
> = End of package |
|